Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer

Product Details
Customization: Available
Warranty: 1 Year
Customized Support: OEM, ODM
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (18)
  • Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
  • Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
  • Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
  • Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
  • Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
  • Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Model NO.
YZ-30R
Material
Metal/ Plastic/Glasses Lens
Voltage
110-240V
Power
Electricity
Name
Applanation Tonometer
Model
Yz-30r
Measuring Range
0~80mmhg
Measurement Accuracy
0.49mn
Dimension
180*80*80mm
Net Weight
500g
Gross Weight
2.5kg
MOQ
1 Unit
Single Package Size
20X10X10 Cm
Single Gross Weight
2.500 Kg
Transport Package
Cardboard Box
Specification
20*10*10cm
Trademark
Brother Medical or Your Brand
Origin
Shanghai
HS Code
9013801000
Production Capacity
12000psc/Year

Product Description

Product Description
Feature
1,Measurement with slit lamp microscope has two effects: checking the eyes and measuring the intraocular pressure.
2,Numerical value is precise. The tonometer's tolerance is only +0.066Kpa.
3,Get numerical value of lOP directly. There is no need to compare theconversion table or make matrix calculation. And Pt='P,
i.e1gPt-1gP0=0.56k, normal k=0.0215, then: Pt:PO=1.0281. So Pt adds 2.8%comparing with PO.
4,The hardness of sclera does not affect the measuring numerical value The change of the eye ball volume is only 0.56mm3.
5,Combined with the measurement method of Schitz tonometer, it canbe used to calculate the hardness of sclera.
6,The measuring-pressure can be calibrated, to ensure the long-termstability and reliability of measurement results.
Detailed Photos
 
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
 
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
Yz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer
 
Product Parameters
Specification Details
Measuring Range 0 ~ 80 mmHg
One Scale Unit 1.96 mN
Measurement Accuracy ±0.49 mN
Repeatability ≤0.50 mN
Reverse Span 0.49 mN
Diameter of Applanation Circle 3.06 mm ±0.02 mm
Diameter of Measuring Prism 7 mm² (Note: This seems to be a misprint, as diameter should be in linear measurement, not area)
Moving Range of Measuring Prism 3 mm
Weight 500 g
Size 180 mm × 80 mm × 80 mm
Yz-30r Ophthalmic Equipment Goldman R Type Applanation TonometerYz-30r Ophthalmic Equipment Goldman R Type Applanation TonometerYz-30r Ophthalmic Equipment Goldman R Type Applanation Tonometer



 